Listing Category Search Page | NSF International

NSF Product and Service Listings

These NSF Official Listings are current as of Wednesday, April 24, 2024 at 12:15 a.m. Eastern Time. Please contact NSF to confirm the status of any Listing, report errors, or make suggestions.

Alert: NSF is concerned about fraudulent downloading and manipulation of website text. Always confirm this information by clicking on the below link for the most accurate information: http://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=46810&Standard=061&



NSF/ANSI/CAN 61
Drinking Water System Components - Health Effects

NOTE: Unless otherwise indicated for Materials, Certification is only for the Water Contact Material shown in the Listing. Click here for a list of Abbreviations used in these Listings. Click here for the definitions of Water Contact Temperatures denoted in these Listings. Products certified to NSF/ANSI/CAN 61 comply with the health effects criteria in NSF/ANSI/CAN 600.


 
Sherwin-Williams Company 
101 Prospect Avenue
Cleveland, OH 44115 
United States 
773-821-3420


Facility : Victorville, CA

Protective (Barrier) Materials

    Water Water
  Water Contact Contact Contact
Trade Designation Size Restriction Temp Material

Coatings - Pipe
Dura-Plate UHS[1] >= 30" CLD 23 EPOXY

[1] Colors: B62H210 gold (primer), B62L210 blue (primer), B62V210 hardener, B62W210 white
    (topcoat), B62W212 ultrawhite (topcoat), B62HW0211 Tannery (topcoat).
    Number of Coats: 2
    Sequence of Coats: Primer, topcoat
    Maximum Field Use Dry Film Thickness (in mils): Primer 10, topcoat 14
    Maximum thinner: 5% Acetone (used with topcoat only)
    Recoat Cure Time and Temperature: 16 hours at 77°F
    Final Cure Time and Temperature: 4 days at 77°F
    Special Comments: Up to 1.5 fl oz of AC0009736 Green or AC0030091 Black may be added to
    5 gal. of mixed product. Mix ratio of Part A:Part B is 4:1 by volume.
    
    Colors: B62W210 White (topcoat), B62V210 (hardener), B62W212 ultrawhite (topcoat),
    B62HW0211 Tannery (topcoat).
    Number of Coats: 1-3
    Maximum Field Use Dry Film Thickness (in mils): 50
    Recoat Cure Time and Temperature: 16 hours at 77°F
    Final Cure Time and Temperature: 4 days at 77°F
    Special Comments: Up to 1.5 fl oz of AC0009736 Green or AC0030091 Black may be added to
    5 gal. of mixed product. Mix ratio of Part A:Part B is 4:1 by volume.

Coatings - Tank
Dura-Plate UHS[1] >= 500 gal. CLD 23 EPOXY

[1] Colors: B62H210 gold (primer), B62L210 blue (primer), B62V210 hardener, B62W210 white
    (topcoat), B62W212 ultrawhite (topcoat), B62HW0211 Tannery (topcoat).
    Number of Coats: 2
    Sequence of Coats: Primer, topcoat
    Maximum Field Use Dry Film Thickness (in mils): Primer 10, topcoat 14
    Maximum thinner: 5% Acetone (used with topcoat only)
    Recoat Cure Time and Temperature: 16 hours at 77°F
    Final Cure Time and Temperature: 4 days at 77°F
    Special Comments: Up to 1.5 fl oz of AC0009736 Green or AC0030091 Black may be added to
    5 gal. of mixed product. Mix ratio of Part A:Part B is 4:1 by volume.
    
    Colors: B62W210 White (topcoat), B62V210 (hardener), B62W212 ultrawhite (topcoat),
    B62HW0211 Tannery (topcoat).
    Number of Coats: 1-3
    Maximum Field Use Dry Film Thickness (in mils): 50
    Recoat Cure Time and Temperature: 16 hours at 77°F
    Final Cure Time and Temperature: 4 days at 77°F
    Special Comments: Up to 1.5 fl oz of AC0009736 Green or AC0030091 Black may be added to
    5 gal. of mixed product. Mix ratio of Part A:Part B is 4:1 by volume.



Facility : Andover, KS

Protective (Barrier) Materials

    Water Water
  Water Contact Contact Contact
Trade Designation Size Restriction Temp Material

Coatings - Pipe
Dura-Plate UHS[1] >= 30" CLD 23 EPOXY
MACROPOXY® 5500 LT [2] >= 108" CLD 23 EPOXY
SherPlate PW[5] >= 12"[4] CLD 23 EPOXY
SherPlate PW[3] >= 6"[4] CLD 23 EPOXY

[1] Colors: B62H210 gold (primer), B62L210 blue (primer), B62W212 ultrawhite (topcoat),
    B62W210 white (topcoat), B62W211 white (topcoat), B62HW0211 Tannery (topcoat), B62V210
    hardener, or B62V211 hardener.
    Number of Coats: 2
    Sequence of Coats: Primer, Topcoat
    Maximum Field Use Dry Thickness (in mils): Primer 10, Topcoat 14
    Maximum Thinner: None
    Recoat Cure Time and Temperature: 16 hours at 77°F
    Final Cure Time and Temperature: 4 days at  77°F
    Special Comments: Up to 1.5 fl oz of AC0009736 Green or AC0030091 Black may be added to
    5 gal. of mixed product. Mix ratio of Part A:Part B is 4:1 by volume.
    
    Colors: B62H210 Gold (Primer), B62W210 White (Topcoat), B62W212 UltraWhite (topcoat),
    B62L210 Blue (Primer), B62W211 White (Topcoat), B62HW0211 Tannery (Topcoat), B62V210
    Hardener or B62V211 Hardener
    Number of Coats: 1 - 3	
    Sequence of Coats: B62W210 (for coat 1); BW2W210, BW2W211 or B62HW0211 (for coats 2 & 3
    if used)
    Maximum Field Use Dry Film Thickness (in mils): 50
    Maximum Thinner: None
    Recoat Cure Time and Temperature: 16 hours at 77°F
    Final Cure Time and Temperature: 4 days at  77°F
    Special Comments: Up to 1.5 fl oz of AC0009736 Green or AC0030091 Black may be added to
    5 gal. of mixed product. Mix ratio of Part A:Part B is 4:1 by volume.
[2] Colors: White, Blue, Beige, Dark Red, Gray, Black
    Number of Coats: 1-3
    Maximum Field Use Dry Thickness(in mils): 28 mils. Max DFT of 1 coat is 15 mils.
    Maximum Thinner: 10% R7K11
    Recoat Cure Time and Temperature: 18 hours at 40F
    Final Cure Time/Temperature: 7 days at 40F
    Special Comments: Mix ratio is 1:1 by volume
[3] Colors: Blue, white
    Number of Coats: 1 - 2
    Sequence of Coats: Any
    Maximum Field Use Dry Film Thickness (in mils): 30 for pipes >= 6"
    Maximum Thinner: None 
    Recoat Cure Time and Temperature: 1 hour at 77°F
    Final Cure Time and Temperature: 10 days at 77°F for coating pipes >= 6"
    Special Comments: Mix ratio of Part A:Part B is 1:1 by volume.
[4] Coatings with a 24 hour final cure time are Certified for use on tanks >= 100 gallons
    and pipes >= 12". Coatings with a 10 day final cure time are Certified for use on pipes
    >= 6".
[5] Colors: Blue, white
    Number of Coats: 1 - 2
    Sequence of Coats: Any
    Maximum Field Use Dry Film Thickness (in mils): 50 for tanks >= 100 gallons and pipes >=
    12"
    Maximum Thinner: None 
    Recoat Cure Time and Temperature: 1 hour at 77°F
    Final Cure Time and Temperature: 24 hours at 77°F for coating tanks >= 100 gallons and
    pipes >= 12"
    Special Comments: Mix ratio of Part A:Part B is 1:1 by volume.

Coatings - Tank
COROTHANE® I GALVAPAC 2K 100 Two Pack Zinc Primer[8] [9] CLD 23 ZINC
Corothane I Galvapac Zinc Primer[6] [7] CLD 23 ZINC
Dura-Plate UHS[1] >= 1000 gal. CLD 23 EPOXY
MACROPOXY® 5500 LT[2] >= 60,000 gal. CLD 23 EPOXY
SherPlate PW[5] >= 100 gal.[4] CLD 23 EPOXY
Zinc Plate Ultra II PCP[10] [11] CLD 23 ZINC

[1] Colors: B62H210 gold (primer), B62L210 blue (primer), B62W212 ultrawhite (topcoat),
    B62W210 white (topcoat), B62W211 white (topcoat), B62HW0211 Tannery (topcoat), B62V210
    hardener, or B62V211 hardener.
    Number of Coats: 2
    Sequence of Coats: Primer, Topcoat
    Maximum Field Use Dry Thickness (in mils): Primer 10, Topcoat 14
    Maximum Thinner: None
    Recoat Cure Time and Temperature: 16 hours at 77°F
    Final Cure Time and Temperature: 4 days at  77°F
    Special Comments: Up to 1.5 fl oz of AC0009736 Green or AC0030091 Black may be added to
    5 gal. of mixed product. Mix ratio of Part A:Part B is 4:1 by volume.
    
    Colors: B62H210 Gold (Primer), B62W210 White (Topcoat), B62W212 UltraWhite (topcoat),
    B62L210 Blue (Primer), B62W211 White (Topcoat), B62HW0211 Tannery (Topcoat), B62V210
    Hardener or B62V211 Hardener
    Number of Coats: 1 - 3	
    Sequence of Coats: B62W210 (for coat 1); BW2W210, BW2W211 or B62HW0211 (for coats 2 & 3
    if used)
    Maximum Field Use Dry Film Thickness (in mils): 50
    Maximum Thinner: None
    Recoat Cure Time and Temperature: 16 hours at 77°F
    Final Cure Time and Temperature: 4 days at  77°F
    Special Comments: Up to 1.5 fl oz of AC0009736 Green or AC0030091 Black may be added to
    5 gal. of mixed product. Mix ratio of Part A:Part B is 4:1 by volume.
[2] Colors: White, Blue, Beige, Dark Red, Gray, Black
    Number of Coats: 1-3
    Maximum Field Use Dry Thickness(in mils): 28 mils. Max DFT of 1 coat is 15 mils.
    Maximum Thinner: 10% R7K11
    Recoat Cure Time and Temperature: 18 hours at 40F
    Final Cure Time/Temperature: 7 days at 40F
    Special Comments: Mix ratio is 1:1 by volume
[4] Coatings with a 24 hour final cure time are Certified for use on tanks >= 100 gallons
    and pipes >= 12". Coatings with a 10 day final cure time are Certified for use on pipes
    >= 6".
[5] Colors: Blue, white
    Number of Coats: 1 - 2
    Sequence of Coats: Any
    Maximum Field Use Dry Film Thickness (in mils): 50 for tanks >= 100 gallons and pipes >=
    12"
    Maximum Thinner: None 
    Recoat Cure Time and Temperature: 1 hour at 77°F
    Final Cure Time and Temperature: 24 hours at 77°F for coating tanks >= 100 gallons and
    pipes >= 12"
    Special Comments: Mix ratio of Part A:Part B is 1:1 by volume.
[6] Colors: B65G10 Gray/Green, B65G11 Gray/Green, B65RX11 Red,  B65RW11 Red
    Number of Coats: 1
    Sequence of Coats: Primer, Topcoat (if applicable)
    Maximum Field Use Dry Film Thickness (in mils): 6
    Maximum Thinner: 10% of R7K15
    Recoat Cure Time and Temperature: 12 hours at 77°F when used as a primer
    Final Cure Time and Temperature: 7 days at 77°F when used as a topcoat
    Special Comments: This primer is Certified as both a single layer and as a primer under
    a topcoat.  B65G10 Mix ratio of A:F is 6.8:21.8 by weight.  B65G11, B65RW11 and B65RX11
    are a one component material and only needs the thinner added.
[7] Certified for use as a single coat in tanks >= 250,000 gallons.
    Certified for use as a primer in any NSF Certified Sherwin-Williams topcoat system in
    tanks 20,000 gallons and greater.
[8] Certified for the following sizes:
    >= 200,000 gallons as a single layer topcoat
    >= 4,000 gallons as a primer with any NSF Certified Sherwin-Williams topcoat
[9] Colors: Green
    Number of Coats: 1
    Sequence of Coats: Primer, topcoat (if applicable)
    Maximum Field Use Dry Film Thickness (in mils): 4
    Maximum Thinner: Up to 10% by volume of Reducer R7K111 
    Recoat Cure Time and Temperature: 12 hours at 77°F when used as a primer
    Final Cure Time and Temperature: 7 days at 77°F when used as a top coat
    Special Comments: This primer is Certified as both a single layer (a top coat) and as a
    primer under a topcoat. Mix ratio of Part A (Binder): Part F (Zinc Dust) is 1.76
    gallons: 73 pounds. Kits are supplied premeasured.
[10] Colors: Gray
     Number of Coats: 1
     Sequence of Coats: Primer, Topcoat
     Maximum Field Use Dry Film Thickness (in mils): 1.5
     Maximum Thinner: 25% R7K58 by weight
     Recoat Cure Time and Temperature: 7 days at 77°F
     Special Comments: Certified as a primer under any NSF Certified top coat. The top coat
     must be used at its Certified end use. Mix ratio of Part A (Binder): Part B (Paste) is
     1.74:1 by volume. Kits are supplied premeasured.
[11] Certified for tanks 200,000 gallons or greater when used as a primer under any NSF
     Certified Sherwin-Williams Coating.


Number of matching Manufacturers is 1
Number of matching Products is 12
Processing time was 0 seconds