DS21T09 by Analog Devices Inc./Maxim Integrated Datasheet | DigiKey

DS21T09 Datasheet by Analog Devices Inc./Maxim Integrated

Hi gAmLul-fi vfi fljjjjfljjfljjjjfl EEEEEEEEEEEEEE 1m
1 of 10 112099
FEATURES
Fully compliant with SCSI-1, Fast SCSI and
Ultra SCSI
Compatible with Plug and Play SCSI Profile
Functional drop in replacement for the
DS2109
Complementary part to DS21T07 for wide
SCSI
Provides active termination for 18 signal lines
2% tolerance on termination resistors and
voltage regulator
Bus termination sensing
Low power-down capacitance of 3 pF
Onboard thermal shutdown circuitry
PIN ASSIGNMENT
DESCRIPTION
The DS21T09 is intended for one-chip Plug and Play (PnP) SCSI termination. Plug and Play SCSI
requires the exit-point terminator on computer motherboards or host bus adapters to automatically switch
off if an external device is connected to the system. The DS21T09 satisfies this requirement by offering
the engineer a choice of onboard current sensing circuitry or onboard ground detect circuitry. If an
external device is connected, the DS21T09 will automatically be isolated from the SCSI bus thereby
maintaining proper system termination.
The DS21T09 integrates a low drop-out regulator, 18 precisely switched 110=termination resistors, and
bus termination sensors into a 28-pin, 300-mil SOIC package. Active termination provides: greater
immunity to voltage drops on the TERMPWR (TERMination PoWeR) line, enhanced high-level noise
immunity, intrinsic TERMPWR decoupling, and very low quiescent current consumption. The DS21T09
contains an output port that can control the power-down pin of additional terminators (DS21T07) for
Wide SCSI applications.
REFERENCE DOCUMENTS
SCSI-2 (X3.131-1994)
SCSI-3 Parallel Interface (X3T10/855D)
Available from: Global Engineering Documents
15 Inverness Way East
Englewood, CO 80112-5704
Phone: (800) 854-7179, (303) 792-2181
Fax: (303) 792-2192
DS21T09
Plug and Play SCSI Terminato
r
www.dalsemi.com
1
2
3
4
5
6
7
8
9
10
11
12
24
27
26
25
23
22
21
20
19
18
17
16
R17
R16
R15
TCS
HS-GND
PDE
R13
R12
R11
R10
V
REF
R14
R2
R3
R4
HS-GND
HS-GND
PDO
R6
R7
R8
R9
TPWR
R5
DS21T09S 28-Pin SOIC
(
300-mil
)
13
14
28
15
PDI
R1
GND
R18
usammomc awonsam: EXIY—MNYYERM‘NAYDR 7)
DS21T09
2 of 10
PnP SCSI Specification
PnP ISA Specification
PnP BIOS Specification
PnP Option ROM Specification
Available from: Plug and Play forum on
CompuServe (Go plugplay).
FUNCTIONAL DESCRIPTION
The DS21T09 is designed to be a single chip termination subsystem for use in PnP SCSI systems, Figure
1. When embedded on a host bus adapter or motherboard, the DS21T09 can automatically sense the
termination status of the SCSI bus and attach or isolate its resistors as needed to maintain proper bus
termination. External and internal active termination can be provided by the DS21T07.
DS21T09 APPLICATION ENVIRONMENT Figure 1
Bus GROUND SENSING cmcurmv DISABLE masts man DOWN BUFFER BUS CURRENT SENSING cumurmv TCS Ru RI! R1
DS21T09
3 of 10
The DS21T09 consists of three major functional blocks, Figure 2:
Voltage reference, terminating resistors, and isolation switches
Bus current sensing circuitry
Bus ground sensing circuitry
When the Bus Ground Sensing Circuitry or Bus Current Sensing Circuitry determines that the SCSI bus
is properly terminated without the DS21T09, the power-down buffer isolates the resistors from the SCSI
bus and disables the power amp, thereby placing the DS21T09 in a low power mode (the bus sensing
circuitry always stays active). The PDO (Power-Down Output) pin can be connected to the pin of a
DS21T07 SCSI terminator for Wide SCSI configurations, Figure 8.
DS21T09 BLOCK DIAGRAM Figure 2
DS21T09
4 of 10
DETAILED PIN DESCRIPTION Table 1
PIN SYMBOL FCN DESCRIPTION
1PDI IPower-Down Internal. For Bus Ground Sensing Circuit, connect to pin
22 of internal SCSI connector; see Figure 4.
2-6,
10-13,
16-19,
24-27
R1…R13
R15…R18
TSignal Termination. 110! termination. Connect to SCSI bus signal
lines. For Bus Current Sensing Circuit connect to data, parity, and
control lines, except SCSI-RST line; see Figure 6.
7, 8, 21 HS-GND P Heat Sink Ground. Internally connected to the mounting pad. Should
be either grounded or electronically isolated from other circuitry.
9PDO OPower-Down Output. Connect to DS21T07 for Wide SCSI
applications; see Figure 8.
14 TPWR P Termination Power. Connect to the SCSI TERMPWR line. Bypass
with a 2.2 µF capacitor; see Figures 4 and 6.
15 VREF OReference Voltage. 2.85-volt reference; must be decoupled with a 4.7
µF capacitor; see Figures 4 and 6.
20 PDE IPower-Down External. For Bus Ground Sensing Circuit, connect to pin
36 of external SCSI connector; see Figure 4.
22 TCS I Termination Current Sense. Used to sense current on the SCSI bus.
For Bus Current Sensing Circuit, connect to SCSI signal line –RST; see
Figure 6.
23 R14 T Signal Termination. 110! termination. Connect to SCSI bus signal
lines. For Bus Current Sensing Circuit connect to SCSI controller chip;
see Figure 6.
28 GND P Ground. Signal ground; 0.0 volts.
ACTIVE TERMINATION
The voltage regulator circuitry (bandgap reference and class AB power amplifier) produces a precise,
laser-trimmed 2.85-volt level and is capable of sourcing 25 mA into each of the terminating resistors
when the signal line is low (active). When the external driver for a given signal line turns off, the active
terminator will pull that signal line to 2.85 volts (quiescent state). When used with an active negation
driver, the power amp can sink 22 mA per line while keeping the voltage reference in regulation; the
terminating resistors maintain their 110=value over the entire voltage range and Vref will move less than
60 mv. To maintain the specified regulation, a 4.7 µF capacitor is required between the VREF pin and
ground. A high frequency capacitor (0.1 µF ceramic recommended) can also be placed on the Vref pin in
applications that use fast rise/fall time drivers. The power down capacitance on terminating resistors R1-
R13 and R15-R18 is <3 pF; R14 is slightly higher due to the bus current sensing circuitry.
The DS21T09 can be removed from the SCSI bus by using either of two automatic methods: Bus Ground
Sensing or Bus Current Sensing.
As with all analog circuitry, the TERMPWR lines should be bypassed locally. A 2.2 µF capacitor is
recommended between TPWR and ground. It should be placed as close as possible to the DS21T09. The
DS21T09 should be placed as close as possible to the connector to minimize signal and power trace
length, thereby resulting in less input capacitance and reflections which can degrade the bus signals.
DISABLE “““ PDE INTERNAL scsn oouuzcron 22 as 155mm 22 “F 032m» W GND PDE TPWR v55; 1 EXTERNAL sacs! CONNECTOR
DS21T09
5 of 10
BUS GROUND SENSING
If internal and external SCSI devices are connected to the SCSI bus, the DS21T09 will disconnect from
the SCSI bus according to the circuit in Figure 3. To utilize this automatic disconnect method of bus
sensing, configure the DS21T09 as shown in Figure 4. The PDI (Power Down Internal) pin should be
connected to pin 22 of the internal SCSI connector, and the PDE (Power Down External) connected to
pin 36 of the external SCSI connector.
BUS GROUND SENSING CIRCUIT Figure 3
BUS GROUND DETECT CONFIGURATION Figure 4
To SCSI CONTROLLER an In ‘— 'ws FROM $55} nus HIST) rcs 110: TU REF >— >— DECODE AND LATCH
DS21T09
6 of 10
BUS CURRENT SENSING
The DS21T09 has the capability to use current sensing to determine if the SCSI bus is over- or under-
terminated. A 1=resistor in series with the SCSI bus (preferable the RST line) is used to monitor the bus
current when that line pulls low (Active or “asserted” state). The resistor is between pad R14 and TCS on
the die. Based on the current measured, the DS21T09 will disconnect or connect from the SCSI bus. The
configuration for this automatic isolation technique is shown in Figure 6.
Figure 5 shows a simplified diagram of the sensing circuit. The voltage across the 1=sense resistor is
differentially amplified and converted into a single-ended voltage with respect to ground. This is fed into
a bank of comparators and measured against a reference voltage. The circuit takes a measurement each
time TCS is driven below a 0.8 volts threshold and the outputs are latched on the rising edge of TCS. If
IBUS is greater than 32 mA, the DS21T09 will be isolated from the SCSI bus. It is recommended that the
signal on TCS be asserted for at least 25 µsec to allow the signal (and comparator outputs) to settle into a
known state. A timing diagram of the sensing and latching operation is shown in Figure 7.
It is preferred that the -RST line be used for monitoring the bus termination status because -RST is only
asserted during power up or during a major change in bus configuration. Note that R14 will have a higher
input capacitance than the other lines because of the additional circuitry required for bus sensing.
The DS21T09 will be isolated from the SCSI bus as shown in Table 2.
BUS CURRENT SENSING CIRCUITRY Figure 5
nmsnuu scan ommecron 25 w TERMPWR 35 0521109 In t .1.— "““ - g: 22 pi . a ma " :5 = R : K2 ‘5 £8 . V" Ru : :5 ms " 4.7 -fisr ”F R14 Gun 4181 sosu CONTROLLER as um um ms mummns LATCH —| 1—
DS21T09
7 of 10
BUS CURRENT SENSE CONFIGURATION Figure 6
BUS CURRENT SENSE TIMING DIAGRAM Figure 7
TERMINATION POWER LINE Is 15 u I: 12 11 ID i mebuh“ 0521101 Io-PIN solo (sou MIL) 4,7 uF l 2.2uF1 :IDPD fit]: I 28:]:IGND juvm— mu: 2 27:]:1H18 :IEINc MEI: a szanw IDES Hal]: 4 zsjljms IRE MEI: s alums EH7 55E]: 9 23335114 :llflns HS—GNDCE 7 22 :Ehcs Ilflramvwaz-fi NS—GNDEI: a 2: :UHS—GND W012]: s NEW BSD: 10 Islflms a7EIE u IsZEIRu RACE 12 VIBE" RsCIE III IEIIZIma TPWHEE u 15 Ivar—J- Dszrms aa-PIN SOIC (ooo MIL) I "7 "F
DS21T09
8 of 10
DISCONNECT MODES Table 2
PDI PDE IBUS > 32 mA? DS21T09 ISOLATED
FROM SCSI BUS?
0 0 No Isolated
0 1 No Connected
1 0 No Connected
1 1 No Connected
00 Yes Isolated
01 Yes Isolated
10 Yes Isolated
11 Yes Isolated
NOTE: “1” denotes pin left open circuited.
WIDE SCSI CONFIGURATION Figure 8
ITP IPD TERV 14 11H 11L
DS21T09
9 of 10
ABSOLUTE MAXIMUM RATINGS*
Voltage on Any Pin Relative to Ground -1.0V to +7.0V
Operating Temperature 0°C to 70°C
Storage Temperature -55°C to +125°C
Soldering Temperature 260°C for 10 seconds
* This is a stress rating only and functional operation of the device at these or any other conditions
above those indicated in the operation sections of this specification is not implied. Exposure to
absolute maximum rating conditions for extended periods of time may affect reliability.
The Dallas Semiconductor DS21T09 is built to the highest quality standards and manufactured for long
term reliability. All Dallas Semiconductor devices are made using the same quality materials and
manufacturing methods. However, the DS21T09 is not exposed to environmental stresses, such as burn-
in, that some industrial applications require. For specific reliability information on this product, please
contact the factory in Dallas at (972) 371-4448.
RECOMMENDED OPERATING CONDITIONS (0°C to 70°C)
PARAMETER SYMBOL MIN TYP MAX UNITS NOTES
TERMPWR Voltage VTP 4.00 5.25 V
Logic 1 VIH 2.0 VTP + 0.3 V 1
Logic 0 VIL -0.3 +0.8 V 1
DC CHARACTERISTICS (0°C to 70°C)
PARAMETER SYMBOL MIN TYP MAX UNITS NOTES
TERMPWR Current ITP
ITP 10
500
14
mA
mA
2, 4
2, 5
Power-Down Current IPD 1 2 mA 2, 3, 6
Termination Resistance RTERM 108 110 112 "2, 3
Die Thermal Shutdown TSD150 °C 2
Power-Down
Termination Capacitance
CPD
C14
8pF
pF
2, 3, 6, 7
2, 3, 6, 7, 8
Input Leakage High IIH -1.0 µA 2, 12
Input Leakage Low IIL 1.0 µA 2, 9, 12
Output Current IO4mA10
Bus Current Sense
Trip Point
IBCST 32 mA 11
REGULATOR CHARACTERISTICS (0°C to 70°C)
PARAMETER SYMBOL MIN TYP MAX UNITS NOTES
Output Voltage VREF 2.79 2.85 2.93 V 2, 3
Drop Out Voltage VDROP 0.75 1.0 V 4, 7
Line Regulation LIREG 1.0 2.0 % 2, 5
Load Regulation LOREG 1.3 3.0 % 2, 3
Current Limit IL900 mA 2
Sink Current ISINK 400 mA 2
’Hfi’H’__ flflflfl E1 H l|JL||J|L_.__ M a A M PKG ZS-PIN
DS21T09
10 of 10
NOTES:
1. PDI , PDE , TCS
2. 4.00V < TERMPWR < 5.50V.
3. 0.0V < signal lines < TERMPWR.
4. All signal lines = 0.0V.
5. All signal lines open.
6. Power down enabled.
7. Guaranteed by design; not production tested.
8. C14 slightly higher capacitance due to
sensing circuitry.
9. Excluding PDI , PDE pins.
10. PDO output pin.
11. IBCST > 32 mA – disable termination.
12. Excluding PDE , PDI , R14, and TCS pins.
28–PIN SOIC (300-MIL)
The chamfer on the body is optional. If it is not
present, a terminal 1 identifier must be
positioned so that ½ or more of its area is
contained in the hatched zone.
PKG 28-PIN
DIM MIN MAX
A IN.
MM 0.094
2.39
0.105
2.67
A1 IN.
MM 0.004
0.102
0.012
0.30
A2 IN.
MM 0.089
2.26
0.095
2.41
b IN.
MM 0.013
0.33
0.020
0.51
C IN.
MM 0.009
0.229
0.013
0.33
D IN.
MM 0.698
17.73
0.712
18.08
e IN.
MM 0.050 BSC
1.27 BSC
E1 IN.
MM 0.290
7.37
0.300
7.62
H IN.
MM 0.398
10.11
0.416
10.57
L IN.
MM 0.016
0.40
0.040
1.02
Θ
ΘΘ