Below is a snapshot of the Web page as it appeared on 4/8/2024 (the last time our crawler visited it). This is the version of the page that was used for ranking your search results. The page may have changed since we last cached it. To see what might have changed (without the highlights), go to the current page.
Bing is not responsible for the content of this page.
Current Transducers NNC-920 .. 960A
For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN = 2000 .. 6000 A
Electrical data
Primary nominal r.m.s. current IPN (A) 2000 3000 4000 5000 6000 Primary current measuring ra More View
nge IP (A) ± ± ± ± ± 2200 3300 4400 5500 6600 Type
Features
920A 930A 940A 950A 960A
NNC NNC NNC NNC NNC
-
• Hall effect measuring principle • Galvanic isolation between primary • Isolation voltage 3000 V~ • Low power consumption
V mA kV 500 and secondary circuit
VC IC Vd Vb V R IS VOUT ROUT RL
Supply voltage (± 5 %) Current consumption R.m.s. voltage for AC isolation test, 50/60Hz, 1 mn R.m.s. rated voltage, safe separation Isolation resistance @ 500 VDC Output voltage @ ± IPN , RL = 10 kΩ , T A = 25°C Output internal resistance Load resistance
± 15 < ± 25 2.5
Advantages
• Easy mounting • Space saving • High immunity to external
interference.
> 1000 100 10
MΩ ± 10 V Ω kΩ
Applications Accuracy - Dynamic performance data
• AC variable speed drives • Battery supplied applications • Uninterruptible Power Supplies
< ± 1 % of IPN < ± 1 % of IPN < ± 50 mV < ± 50 <±1 < ± 0.1 < 25 mV mV/°C %/°C µs (UPS)
ε
XG
L
VO E VOH VOT TCε G tr
Accuracy @ T A = 25°C Linearity (0 .. ± IPN ) Electrical offset voltage, T A = 25°C Hysteresis offset voltage @ IP = 0; after an excursion of 1 x IPN Thermal drift of VOE Thermal drift of the gain (% of reading) Response time @ 90% of IP
General data
TA TS m Ambient operating temperature Ambient storage temperature Mass - 10 .. + 60 - 15 .. + 65 1.4 °C °C kg
Notes : Linearity data exclude the electrical offset.
010301/1 www.nanalem.co.jp
NNC-920 .. 960A
UNIT: mm
NANALEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.