Part | LV100-250_03 |
Category | |
Description | Voltage Transducer LV 100-900 |
Company | LEM |
Datasheet | Download LV100-250_03 Datasheet |
Features, Applications |
For the electronic measurement of voltages : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high voltage) and the secondary circuit (electronic circuit). VPN VP IPN RM Primary nominal r.m.s. voltage Primary voltage, measuring range Primary nominal r.m.s. current Measuring resistance with 15 V ISN 900 V max 1350 V max R M min R M max FeaturesSecondary nominal r.m.s. current Conversion ratio Supply voltage 5 Current consumption R.m.s. voltage for AC isolation test, 50 Hz, 1 mn Excellent accuracyVery good linearityLow thermal driftHigh immunity to externalOverall Accuracy @ VPN = 25�C Linearity Offset current = 25�C Thermal drift of IO Response time of VP max ApplicationsStatic converters for DC motor drivesUninterruptible Power Supplies RS m Ambient operating temperature Ambient storage temperature Turns ratio Total primary power loss Primary resistance = 25�C Secondary coil resistance = 70�C Mass Standards k g Terminal + : supply voltage 15 V Terminal M : measure Terminal - : supply voltage 15 V Terminal : ground or earth General toleranceFasteningConnection of primaryConnection of secondaryConnection to the groundFastening torque mm 2 holes mm M5 threaded studs Faston mm M5 threaded stud or 1.62 Lb. -Ft.IS is positive when VP is applied on terminal +HT.The primary circuit of the transducer must be linked to the This is a standard model. For different versions (supplyvoltages, turns ratios, unidirectional measurements...), please contact us. LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. |
Related products with the same datasheet |
LV100-1000 |
LV100-1000_03 |
LV100-100_03 |
LV100-1200 |
LV100-1200_03 |
LV100-150 |
LV100-1500 |
LV100-1500_03 |
LV100-150_03 |
LV100-1600 |
LV100-1600_03 |
LV100-200 |
Some Part number from the same manufacture LEM |
LV100-300 Voltage Transducer LV 100-900 |
AP50-B10 AC Current Transducer Ap-b420l |
HTC2000-S Current Transducers |
HAX600-S Current Transducer |
AKR-B420L AC Current Transducer |
HY05-P/SP1 Current Transducers HY 5 to 25-p/sp1 |
AK50B420L AC Current Transducer |
AKR5B420L |
DHR600C10 Ac/dc Current Transducer |
HNC-300P Current Transducer |
HX15-P Current Transducer HX 03~50-p/sp2 |
DK300B020 DC Current Transducer |
LAS100-TP Current Transducer |
DF0.5-C10 DC Current Transducer Df-c10 |
AK200B5 AC Current Transducer |
AP100-B10 AC Current Transducer Ap-b420l |
AHR1500B10 Ac/dc Current Transducer |
HAS600-P Current Transducer |
HAS300-P |
HAIS100-P |
HY5P Current Transducers HY 5 to 25-p/sp1 |
HAC500-S : Current Transducers CT0.4-P : Current Transducers HAZ12000-SRU : Current Transducers HTFS200-SP2 : Current Transducer HTA1000-S : Current Transducer HAX1000-S : Current Transducer HY12-P : Current Transducers HY 5 to 25-p/sp1 AK200C420L : AC Current Transducer AHR-B420 : Ac/dc Current Transducer AHR800B10 : Ac/dc Current Transducer HY 15-P : CURRENT TRANSDUCER, 15A Specifications: Current Measuring Range AC: -45A to 45A ; Current Measuring Range DC: -45A to 45A ; Operating Pressure Range: - ; Operating Frequency Range: - ; Supply Voltage Range DC: � 12V to � 15V ; Sensor Output: Voltage ; Accuracy %: 1% ; Response Time: 3�s ART-B22-D300 : FLEXIBLE ROGOWSKI COIL 300MM LEM's ART series offers smart grid solutions with galvanic isolation between power and measurement circuits. All while dramatically reducing error with LEM’s patented perfect loop technology. The ART series provides ease of use with its flexible clip-around application for a wide range of c |