2003 - F1251T
Abstract: F0500T F0500Z8 F1250T F1250Z8 F1251Z8 3 phase fuse board
Text: not rated 75 45 35 F1250Z8 500 160 115 100 F1251Z8 500 160 115 , * 1 ms 2 ms 60 ms F1251Z8 250 V 2A 30 A2s 600 V, 60 A * 1 ms 2 ms 60 ms , MAX F0500Z8 0.471 V 0.420 0.640 F1250Z8 0.205 V 0.107 0.150 F1251Z8 , TeleLink Fuse Qualification Data The F1250Z8 and F1251Z8 meet the following test conditions per GR 1089 , Fuse Temperature Reading F0500Z8 75 °C (167 °F) * F1250Z8 75 °C (167 °F) * F1251Z8
|
Original
|
PDF
|
F0500T,
F1250T,
F1251T
10x160
10x560
10x1000
F0500Z8
F1250Z8
F1251Z8
F1250Z8
F0500T
F0500Z8
F1250T
F1251Z8
3 phase fuse board
|
2004 - Not Available
Abstract: No abstract text available
Text: 35 100 100 TeleLink SM Fuse F0500Z8 (0461 .500) F1250Z8 (0461 1.25) F1251Z8 (0461 002 , ) F1250Z8 (0461 1.25) F1251Z8 (0461 002.) * Interrupt test characterized at 50° to 70° phase angle. Phase , 16.7 ms. Resistance Ratings TeleLink SM Fuse F0500Z8 F1250Z8 F1251Z8 Typical Voltage Drop @ Rated
|
Original
|
PDF
|
10x160
10x560
10x1000
F0500Z8
F1250Z8
F1251Z8
F0500Z8
F1250Z8
F1251Z8
|
2004 - F0500Z8
Abstract: F1250Z8 F1251Z8
Text: F1251Z8 (0461 002.) 500 160 115 100 Interrupting Values TeleLink SM Fuse Voltage , 1.25) 250 V 1.25 A 22.2 A2s 600 V, 60 A * 1 ms 2 ms 60 ms F1251Z8 (0461 002 , F0500Z8 0.471 V 0.420 0.640 F1250Z8 0.205 V 0.107 0.150 F1251Z8 0.110 V , Qualification Data The F1250Z8 and F1251Z8 meet the following test conditions per GR 1089 without additional , 75 °C (167 °F) * F1250Z8 75 °C (167 °F) * F1251Z8 75 °C (167 °F) * * Higher currents
|
Original
|
PDF
|
10x160
10x560
10x1000
F0500Z8
F1250Z8
F1251Z8
F1250Z8
F0500Z8
F1251Z8
|
2004 - tip 17
Abstract: No abstract text available
Text: Four-port TeleLink Fuse Temperature Derating Curve Operating temperature is -55 °C to +125 °C with proper correction factor applied. 150 140 130 120 Percent of Rating 110 100 90 80 70 60 50 40 30 -55 -60 -40 -20 0 20 40 60 80 100 125 Effect on Current Rating Ambient °C Chart of Correction Factor Maximum Temperature Rise TeleLink Fuse F0500Z8 F1250Z8 F1251Z8 * Higher currents and PCB layout designs can affect this parameter. Notes: · Readings are measured at rated current after
|
Original
|
PDF
|
F0500Z8
F1250Z8
F1251Z8
tip 17
|
2004 - TELELINK
Abstract: No abstract text available
Text: Four-port TeleLink Fuse Qualification Data The F1250Z8 and F1251Z8 meet the following test conditions per GR 1089 without additional series resistance. However, in-circuit test verification is required. Note that considerable heating may occur during Test 4 of the Second Level AC Power Fault Test. First Level Lightning Surge Test 1 2 3 4 5 ±600 ±1000 ±1000 ±2500 ±1000 10x1000 10x360 10x1000 2x10 10x360 100 100 100 500 25 25 25 25 10 5 Second Level Lightning Surge Test Test 1 Surge
|
Original
|
PDF
|
F1250Z8
F1251Z8
10x1000
10x360
10x360
TELELINK
|
2003 - DIODE P31B
Abstract: P61a p31b diode p26b p31b p482a p-8cm DIODE P31A P06C diode p35b
Text: No file text available
|
Original
|
PDF
|
DO-214AA
DO-214AA
F1250T
F0500T
F1250T
F1251T
DIODE P31B
P61a
p31b diode
p26b
p31b
p482a
p-8cm
DIODE P31A
P06C diode
p35b
|
2003 - p1806
Abstract: COACH P3000AA61 Teccor A1220U A1225U A2106A A2106U A2106Z A5030A
Text: 2-54 P1402AC MC 2-32 P2103A_ 2-34 F1251Z8 2-48 P0721S_ 2-52 P1402C_ 2-12
|
Original
|
PDF
|
|
2004 - P-8CM
Abstract: IC P605 8 pin DIODE P31A "triac protection" overcurrent MOV surge protection circuit diagram p31b DIODE P31B Teccor P0080SC MC marking code diode s4 do-214 P3100EB
Text: 2-54 P1402AC MC 2-32 P2000AA61 2-28 F1251Z8 2-48 P0721S_ 2-52 P1402C
|
Original
|
PDF
|
E133083
E191008
O-220
P-8CM
IC P605 8 pin
DIODE P31A
"triac protection" overcurrent
MOV surge protection circuit diagram
p31b
DIODE P31B
Teccor P0080SC MC marking code
diode s4 do-214
P3100EB
|