ALCATEL-LUCENT OMNISWITCH 6560 HARDWARE USER'S MANUAL Pdf Download | ManualsLib
Alcatel-Lucent OmniSwitch 6560 Hardware User's Manual

Alcatel-Lucent OmniSwitch 6560 Hardware User's Manual

Hide thumbs Also See for OmniSwitch 6560:
Table of Contents

Advertisement

Part No. 060474-10, Rev. G
December 2019
OmniSwitch 6560
Hardware Users Guide
www.al-enterprise.com

Advertisement

Table of Contents
loading

Summary of Contents for Alcatel-Lucent OmniSwitch 6560

  • Page 1 Part No. 060474-10, Rev. G December 2019 OmniSwitch 6560 Hardware Users Guide www.al-enterprise.com...
  • Page 2 This user guide documents OmniSwitch 6560 hardware, including chassis and associated components. The specifications described in this guide are subject to change without notice. The Alcatel-Lucent name and logo are trademarks of Nokia used under license by ALE. To view other trademarks used by affiliated companies of ALE Holding, visit: www.al-enterprise.com/en/legal/ trademarks-copyright.
  • Page 3: Table Of Contents

    How is the Information Organized? ................... x Documentation Roadmap ....................xi Related Documentation ....................xiii Technical Support ......................xiv Chapter 1 OmniSwitch 6560 ...................... 1-1 OmniSwitch 6560 Availability Features .................1-3 Power Supply Redundancy ..................1-3 Hot-Swapping ......................1-3 Hardware Monitoring ....................1-3 Chapter 2 Getting Started ......................2-1 Installing the Hardware ....................2-1...
  • Page 4 Specifying the Switch’s Location ..............2-9 Viewing Your Changes ..................2-10 Saving Your Changes .....................2-10 Chapter 3 Chassis and Power Supplies ..................3-1 OmniSwitch 6560 Chassis Details ..................3-2 OS6560-P24Z8 ......................3-2 OS6560-P24Z8 Front Panel ................3-2 OS6560-P24Z8 Rear Panel ................3-2 OS6560-P24Z8 Chassis Specifications .............3-3 OS6560-P24Z24 .......................3-4 OS6560-P24Z24 Front Panel ................3-4...
  • Page 5 OS6560-BP LED States ..................3-35 OS6560-BP-D 150W DC Power Supply ...............3-36 OS6560-BP-D LED States ................3-36 OmniSwitch 6560 Internal Power Supply ..............3-37 DC Power Supply Connections ................3-38 Connecting a DC Cable Harness to the Chassis Power Supply ......3-38 Connecting a DC Cable Harness to the DC Power Source ......3-38 Installing Power Supplies ..................3-39...
  • Page 6 Invisible Laser Radiation Warning ..............A-10 Operating Voltage Warning ................A-10 Power Disconnection Warning ............... A-10 Proper Earthing Requirement Warning ............A-11 DC Power Supply Connection Warning ..............A-11 Read Important Safety Information Warning ..........A-12 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 7 Advertencia sobre una apropiada conexión a tierra ........A-14 Leer “información importante de seguridad” ..........A-14 Advertencia de acceso restringido ..............A-14 Advertencia de pulsera antiestática ..............A-14 Clase de seguridad ..................A-14 Advertencia de fuentes de poder ..............A-14 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 8 Contents viii OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 9: About This Guide

    About This Guide This OmniSwitch 6560 Hardware Users Guide describes OmniSwitch 6560 switch components and basic switch hardware procedures. Supported Platforms The information in this guide applies only to OmniSwitch 6560 switches. Who Should Read this Manual? The audience for this users guide is network administrators and IT support personnel who need to configure, maintain, and monitor switches and routers in a live network.
  • Page 10: What Is In This Manual

    Each chapter in this guide focuses on a specific hardware component or a set of hardware components. All descriptive, technical specification, and procedural information for a hardware component can be found in the chapter dedicated to that component. OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 11: Documentation Roadmap

    Pertinent Documentation: Getting Started Information OmniSwitch 6560 Release Notes A “Getting Started” chapter is included in the OmniSwitch 6560 Hardware Users Guide. This chapter provides all the information you need to get your switch up and running the first time. It also includes succinct overview information on fundamental aspects of the switch.
  • Page 12 This guide includes syntax, default, usage, example, related CLI command, and CLI-to-MIB variable mapping information for all CLI commands supported by the switch. This guide can be consulted anytime during the configuration process to find detailed and specific information on each CLI command. OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 13: Related Documentation

    Related Documentation The following are the titles and descriptions of all the OmniSwitch 6560 user manuals: OmniSwitch 6560 Hardware Users Guide • Complete technical specifications and procedures for all OmniSwitch 6560 chassis, power supplies, fans, and Network Interface (NI) modules.
  • Page 14: Technical Support

    (open or closed) that you have reported to technical support, open a new case or access helpful release notes, technical bulletins, and manuals. Access additional information can be found below: Web: businessportal2.alcatel-lucent.com Phone: 1-800-995-2696 Email: ebg_gloabl_supportenter@al-enterprise.com OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 15: Chapter 1 Omniswitch 6560

    1 OmniSwitch 6560 Refer to the information below for OmniSwitch 6560 models and components. Model Number Description OS6560-P24Z8 Fixed-configuration chassis in a 1U form factor with: 16 - RJ45 10/100/1000 Base-T PoE ports (802.3at) • 8 - RJ45 100/1G/2.5G BaseT PoE ports (802.3bt) •...
  • Page 16 2 - SFP+ 1G/10G ports • 2 - SFP+ 10G ports • OS6560-X10 Fixed-configuration chassis in a 1U form factor with: 8 - SFP+ 1G/10G ports • 2 - 20G QSFP+ VFL ports • page 1-2 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 17: Omniswitch 6560 Availability Features

    The user enters “show” commands that output information to the console. The show commands for all the features are described in detail in the OmniSwitch CLI Reference Guide. OmniSwitch 6560 Hardware Users Guide December 2019 page 1-3...
  • Page 18 OmniSwitch 6560 Availability Features OmniSwitch 6560 page 1-4 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 19: Chapter 2 Getting Started

    2 Getting Started Installing the Hardware Note. For information on configuring a Virtual Chassis (VC), refer to the OmniSwitch 6560 Switch Management Guide. Items Required Grounding wrist strap • Phillips screwdriver • Flat-blade screwdriver • Site Preparation Environmental Requirements The switches have the following environmental and airflow requirements: The installation site must maintain a supported temperature and humidity range as given in the •...
  • Page 20: Electrical Surge Warning

    Ethernet cables (especially in new cable runs) to a suitable and safe earth ground before connect- ing them to the port. Note. Failure to follow the above recommendations could result in voiding the warranty of the affected ALE product. page 2-2 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 21: Unpacking And Installing The Switch

    Rubber table-mounting feet • Attachment screws • Assorted instructional cards, anti-static bags and additional packaging • Weight Considerations Weights vary depending on model type. Please refer to the chassis specifications table. OmniSwitch 6560 Hardware Users Guide December 2019 page 2-3...
  • Page 22: Airflow Considerations

    Note. Clearance is not required at the top and bottom of the chassis. Mounting the Switch For information on mounting the switches, refer to the Chapter 3, “Chassis and Power Supplies.” page 2-4 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 23: Connections And Cabling

    By default, this connector provides a DCE console connection. Serial Connection Default Settings baud rate 9600 parity none data bits (word size) stop bits For information on modifying these settings, refer to the OmniSwitch 6560 Switch Management Guide. OmniSwitch 6560 Hardware Users Guide December 2019 page 2-5...
  • Page 24: Booting The Switch

    Once the switch has completely booted and you have accessed your computer’s terminal emulation software via the console port, you are ready to log in to the switch’s Command Line Interface (CLI) and configure basic information. Continue to “Your First Login Session” on page 2-7. page 2-6 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 25: Your First Login Session

    Note. A user account includes a login name, password, and user privileges. Privileges determine whether the user has read or write access to the switch and which commands the user is authorized to execute. For detailed information on setting up and modifying user accounts, refer to the OmniSwitch 6560 Switch Management Guide.
  • Page 26: Unlocking Session Types

    Note. When you unlock session types, you are granting switch access to non-local sessions (e.g., Telnet). As a result, users who know the correct user login and password will have remote access to the switch. For more information on switch security, refer to the OmniSwitch 6560 Switch Management Guide. Unlocking All Session Types To unlock all session types, enter the following command syntax at the CLI prompt: ->...
  • Page 27: Setting The System Time Zone

    Daylight Savings Time (DST) on the switch, you can configure these settings via the system timezone and system daylight-savings-time commands. For detailed information on configuring a time zone for the switch, refer to the OmniSwitch 6560 Switch Management Guide.
  • Page 28: Viewing Your Changes

    To view your current changes, enter show system at the CLI prompt. Saving Your Changes Once you have configured this basic switch information, save your changes by entering write memory at the CLI command prompt. page 2-10 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 29 Switch mounting information, page 3-24. • Power supplies and power supply redundancy, page 3-32. • Temperature management, page 3-44. • Monitoring the chassis components via the Command Line Interface (CLI), page 3-44 • OmniSwitch 6560 Hardware Users Guide December 2019 page 3-1...
  • Page 30: Omniswitch 6560 Chassis Details

    CLASS 1 M LASER CAUTION. CAUTION - CLASS 1 M LASER RADIATION WHEN OPEN. DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS OS6560-P24Z8 Rear Panel Item Description Chassis Grounding Lug Fans Power Supplies page 3-2 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 31: Os6560-P24Z8 Chassis Specifications

    *Note On Chassis Versus Ambient Temperatures. Chassis temperature refers to the sensor reading of the internal switch temperature (threshold or danger). Ambient temperature refers to the approximate room temperature. The ambient temperature will typically be lower than the chassis temperature. OmniSwitch 6560 Hardware Users Guide December 2019 page 3-3...
  • Page 32: Os6560-P24Z24

    CLASS 1 M LASER CAUTION. CAUTION - CLASS 1 M LASER RADIATION WHEN OPEN. DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS OS6560-P24Z24 Rear Panel Item Description Chassis Grounding Lug Fans Power Supplies page 3-4 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 33: Os6560-P24Z24 Chassis Specifications

    *Note On Chassis Versus Ambient Temperatures. Chassis temperature refers to the sensor reading of the internal switch temperature (threshold or danger). Ambient temperature refers to the approximate room temperature. The ambient temperature will typically be lower than the chassis temperature. OmniSwitch 6560 Hardware Users Guide December 2019 page 3-5...
  • Page 34 CLASS 1 M LASER CAUTION. CAUTION - CLASS 1 M LASER RADIATION WHEN OPEN. DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS OS6560-P24X4 Rear Panel Item Description Chassis Grounding Lug Fans Power Supplies page 3-6 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 35 *Note On Chassis Versus Ambient Temperatures. Chassis temperature refers to the sensor reading of the internal switch temperature (threshold or danger). Ambient temperature refers to the approximate room temperature. The ambient temperature will typically be lower than the chassis temperature. OmniSwitch 6560 Hardware Users Guide December 2019 page 3-7...
  • Page 36 CLASS 1 M LASER CAUTION. CAUTION - CLASS 1 M LASER RADIATION WHEN OPEN. DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS OS6560-P48X4 Rear Panel Item Description Chassis Grounding Lug Fans Power Supplies page 3-8 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 37 *Note On Chassis Versus Ambient Temperatures. Chassis temperature refers to the sensor reading of the internal switch temperature (threshold or danger). Ambient temperature refers to the approximate room temperature. The ambient temperature will typically be lower than the chassis temperature. OmniSwitch 6560 Hardware Users Guide December 2019 page 3-9...
  • Page 38: Os6560-P48Z16

    CLASS 1 M LASER CAUTION. CAUTION - CLASS 1 M LASER RADIATION WHEN OPEN. DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS OS6560-P48Z16 Rear Panel Item Description Chassis Grounding Lug Fan Vent Power Supplies page 3-10 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 39: Os6560-P48Z16 Chassis Specifications

    *Note On Chassis Versus Ambient Temperatures. Chassis temperature refers to the sensor reading of the internal switch temperature (threshold or danger). Ambient temperature refers to the approximate room temperature. The ambient temperature will typically be lower than the chassis temperature. OmniSwitch 6560 Hardware Users Guide December 2019 page 3-11...
  • Page 40: Os6560-24Z8

    CLASS 1 M LASER CAUTION CAUTION - CLASS 1 M LASER RADIATION WHEN OPEN. DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS OS6560-24Z8 Rear Panel Item Description Chassis Grounding Lug Fans Power Supplies page 3-12 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 41: Os6560-24Z8 Chassis Specifications

    *Note On Chassis Versus Ambient Temperatures. Chassis temperature refers to the sensor reading of the internal switch temperature (threshold or danger). Ambient temperature refers to the approximate room temperature. The ambient temperature will typically be lower than the chassis temperature. OmniSwitch 6560 Hardware Users Guide December 2019 page 3-13...
  • Page 42: Os6560-24Z24

    CLASS 1 M LASER CAUTION. CAUTION - CLASS 1 M LASER RADIATION WHEN OPEN. DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS OS6560-24Z24 Rear Panel Item Description Chassis Grounding Lug Fans Power Supplies page 3-14 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 43: Os6560-24Z24 Chassis Specifications

    *Note On Chassis Versus Ambient Temperatures. Chassis temperature refers to the sensor reading of the internal switch temperature (threshold or danger). Ambient temperature refers to the approximate room temperature. The ambient temperature will typically be lower than the chassis temperature. OmniSwitch 6560 Hardware Users Guide December 2019 page 3-15...
  • Page 44: Os6560-24X4

    CLASS 1 M LASER CAUTION. CAUTION - CLASS 1 M LASER RADIATION WHEN OPEN. DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS OS6560-24X4 Rear Panel Item Description Chassis Grounding Lug Fans Power Supply Connector (Internal AC Power Supply) Backup Power Supply Slot (Modular) page 3-16 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 45: Os6560-24X4 Chassis Specifications

    *Note On Chassis Versus Ambient Temperatures. Chassis temperature refers to the sensor reading of the internal switch temperature (threshold or danger). Ambient temperature refers to the approximate room temperature. The ambient temperature will typically be lower than the chassis temperature. OmniSwitch 6560 Hardware Users Guide December 2019 page 3-17...
  • Page 46: Os6560-48X4

    CLASS 1 M LASER CAUTION. CAUTION - CLASS 1 M LASER RADIATION WHEN OPEN. DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS OS6560-48X4 Rear Panel Item Description Chassis Grounding Lug Fans Power Supply Connector (Internal AC Power Supply) Backup Power Supply Slot (Modular) page 3-18 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 47: Os6560-48X4 Chassis Specifications

    *Note On Chassis Versus Ambient Temperatures. Chassis temperature refers to the sensor reading of the internal switch temperature (threshold or danger). Ambient temperature refers to the approximate room temperature. The ambient temperature will typically be lower than the chassis temperature. OmniSwitch 6560 Hardware Users Guide December 2019 page 3-19...
  • Page 48: Os6560-X10

    CLASS 1 M LASER CAUTION. CAUTION - CLASS 1 M LASER RADIATION WHEN OPEN. DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS OS6560-X10 Rear Panel Item Description Chassis Grounding Lug Fans Internal Power Supply Modular Power Supply page 3-20 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 49: Os6560-X10 Chassis Specifications

    *Note On Chassis Versus Ambient Temperatures. Chassis temperature refers to the sensor reading of the internal switch temperature (threshold or danger). Ambient temperature refers to the approximate room temperature. The ambient temperature will typically be lower than the chassis temperature. OmniSwitch 6560 Hardware Users Guide December 2019 page 3-21...
  • Page 50: Chassis Status Leds

    Valid port link with activity (non-PoE) Solid Amber Valid port link (PoE) Blinking Amber Valid port link with activity (PoE) SFP+ Port LEDs Solid Green Valid port link Blinking Green Valid port link with activity page 3-22 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 51 Solid Amber (Speed LED 1) 100/1000 valid port link Blinking Amber (Speed LED 1) 100/1000 valid port link with activity Solid Amber (PoE LED 2) PoE Enabled Off (PoE LED 2) PoE Disabled OmniSwitch 6560 Hardware Users Guide December 2019 page 3-23...
  • Page 52: Mounting The Switch

    Reliable Earthing. Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch (e.g., use of power strips). page 3-24 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 53: Airflow Recommendations

    Sides. 2 inches minimum at left and right sides. Front. 6 inches minimum at front of chassis. Chassis Top View Note. Clearance is not required at the top and bottom of the chassis. OmniSwitch 6560 Hardware Users Guide December 2019 page 3-25...
  • Page 54: Blank Cover Panels

    When installing blank cover panels over power supply slots, orient the cover panels with the arrows pointing up. Face arrow up when installing. Insert the blank cover panel in the empty chassis slot and secure using attachment screws (provided). page 3-26 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 55: Rack-Mounting

    The chassis has rack-mount flanges that support standard 19-inch rack mount installations. • Alcatel-Lucent Enterprise does not provide rack-mount screws. Use the screws supplied by the • rack vendor.
  • Page 56 Clip in “In” (engaged) position “CLICK” Secure the flange to the chassis using the attachment screw (provided). Repeat steps 1 through 4 for the flange on the opposite side of the chassis. page 3-28 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 57: Installing The Chassis In The Rack

    Once the holes are aligned, the second person should insert a screw through the bottom hole on each flange. Tighten both screws until they are secure. Install the remaining screws in the top hole of each flange. Be sure that all screws are securely tightened. OmniSwitch 6560 Hardware Users Guide December 2019 page 3-29...
  • Page 58: Standalone (Non-Rack Mounted) Installations

    Place the switch on the tabletop “right side up.” Note. Never attempt to operate a switch while it is placed on its top or side. Connect network and management cables as needed. page 3-30 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 59: Power Supplies

    Chassis and Power Supplies Power Supplies Power Supplies OmniSwitch 6560 switches can use the following power supply types: Model Chassis Supported OS6560-BP-P 300W AC OS6560-P24Z8, OS6560-P24Z24, OS6560-P24X4, OS6560-P48X4, PoE PSU OS6560-P48Z16 (903954-90/904044-90) OS6560-BP-PH 600W AC OS6560-P24Z8, OS6560-P24Z24, OS6560-P24X4, OS6560-P48Z16 PoE PSU (903852-90)
  • Page 60: Os6560-Bp-P 300W Power Supply

    AC OK LED Solid Red There is an AC power issue DC OK LED Solid Green DC power is good DC OK LED Solid Red There is a DC power issue page 3-32 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 61: Os6560-Bp-Ph 600W Power Supply

    AC OK LED Solid Red There is an AC power issue DC OK LED Solid Green DC power is good DC OK LED Solid Red There is a DC power issue OmniSwitch 6560 Hardware Users Guide December 2019 page 3-33...
  • Page 62: Os6560-Bp-Px 920W Power Supply

    AC OK LED Solid Red There is an AC power issue DC OK LED Solid Green DC power is good DC OK LED Solid Red There is a DC power issue page 3-34 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 63: Os6560-Bp 150W Ac Power Supply

    Flashing Green/Red Power supply warning Solid Red Power supply failure No AC power is being provided to any power supply installed in the chassis; all power supplies are effectively off OmniSwitch 6560 Hardware Users Guide December 2019 page 3-35...
  • Page 64: Os6560-Bp-D 150W Dc Power Supply

    Flashing Green/Red Power supply warning Solid Red Power supply failure No power is being provided to any power supply installed in the chassis; all power supplies are effectively off page 3-36 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 65: Omniswitch 6560 Internal Power Supply

    Chassis and Power Supplies Power Supplies OmniSwitch 6560 Internal Power Supply Model Internal AC Power Supply Models Supported “Power Supplies” Input Voltage/Frequency/Cur- 100-240 VAC/50-60Hz/1.5 A rent Output Power/Voltage/Current 65W/12VDC/5.42A OmniSwitch 6560 Hardware Users Guide December 2019 page 3-37...
  • Page 66: Dc Power Supply Connections

    Observe proper polarity when connecting to a fuse panel. The cable wire leads must be connected as follows: Green/yellow - ground • Black - return • Red - -48VDC • Note. The battery return conductor is an Isolated DC Return (DC-1). page 3-38 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 67: Installing Power Supplies

    When the connector is fully seated, the lock tab will click and hold the power supply in place. Lock Tab Plug the power cord (provided) into the power supply’s socket. OmniSwitch 6560 Hardware Users Guide December 2019 page 3-39...
  • Page 68 Power Supplies Chassis and Power Supplies Note. The chassis does not provide an on/off switch. Connecting a the power supplies to a power source will boot the switch. page 3-40 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 69: Removing Power Supplies

    Pressing the lock tab toward the center of the power supply, as shown, will free the power supply from the chassis. Lock Tab OmniSwitch 6560 Hardware Users Guide December 2019 page 3-41...
  • Page 70 While pressing the lock tab, pull the power supply straight back and out of the chassis slot. Note. If you are not replacing the power supply, be sure to install a blank cover panel over the empty power supply bay. page 3-42 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 71: Grounding The Chassis

    Use this connector to supplement the ground provided by the AC power cord. To do so, install a Panduit Grounding Lug (type LCD8-10A-L) using 8AWG copper conductors to the paint-free area. Refer to the rear chassis views on page 3-2 for location details. OmniSwitch 6560 Hardware Users Guide December 2019 page 3-43...
  • Page 72: Monitoring Chassis Components

    15-93 UNDER THRESHOLD 2/CMMA 15-85 UNDER THRESHOLD 2/Slot1 15-85 UNDER THRESHOLD For more information about this command, see the “Chassis Management and Monitoring Commands” chapter in the OmniSwitch CLI Reference Guide. page 3-44 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 73: Temperature Errors

    Primary power supply failure and then backup power supply failure • Backup power supply failure and then primary power supply failure • Note. Connect each power supply to a separate independent power source to avoid simultaneous power failures. OmniSwitch 6560 Hardware Users Guide December 2019 page 3-45...
  • Page 74: Snmp Trap

    It may not be possible to generate PDUs on all ports enabled for link OAM. Dying gasp packets will be sent in the following order based on port priority: 1. Uplink ports 2. All other ports page 3-46 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 75: Chapter 4 Managing Power Over Ethernet (Poe)

    Important. It’s recommended that PoE-enabled switches with attached IP telephones should have opera- tional power supply redundancy at all times for 911 emergency requirements. In addition, both the switch and the power supply should be plugged into an Uninterruptible Power Source (UPS). OmniSwitch 6560 Hardware Users Guide December 2019 page 4-1...
  • Page 76: In This Chapter

    Note. You can also monitor all chassis components and manage many chassis features, including Power over Ethernet, with WebView, Alcatel-Lucent’s embedded web-based device management application. WebView is an interactive and easy-to-use GUI that can be launched from the OmniVista or a web browser.
  • Page 77: Power Over Ethernet Specifications

    Managing Power over Ethernet (PoE) Power over Ethernet Specifications Power over Ethernet Specifications The table below lists general specifications for Alcatel-Lucent’s Power over Ethernet support. For more detailed power supply and Power Source Equipment (PSE) specifications, refer to Chapter 3, “Chassis and Power Supplies.”...
  • Page 78: Power Over Ethernet Budget

    Viewing Power Supply Status To view the type and status for installed power supplies, use the show powersupply command: -> show powersupply Total Chassis/PS Power Type Status Location -----------+---------+--------+--------+----------- Internal Total page 4-4 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 79: Viewing Poe Status

    Powered devices can be classified into different classes as shown in the table below. Class detection allows for automatic maximum power adjustment based on the power class detected. This will prevent the switch from delivering more than the maximum power allowed based on a device’s class. OmniSwitch 6560 Hardware Users Guide December 2019 page 4-5...
  • Page 80: Poe Operational Status

    Note. You cannot use the lanpower port admin-state command to initially activate PoE on a port. This syntax is intended only to reactivate power to those that have been disconnected via the lanpower slot page 4-6 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 81: Configuring The Total Power Available To A Port

    3, slot 1 to 400 watts. This value is now the maximum amount of power the slot can use to power all attached devices (until the value is modified by the user). OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 82: Setting Port Priority Levels

    Note. The capacitive detection method should only be enabled to support legacy IP phones. This feature is not compatible with IEEE specifications. Please contact your Alcatel-Lucent sales engineer or Customer Support representative to find out which Alcatel-Lucent IP phones models need capacitive detection enabled.
  • Page 83 PDs in the case of the power budget being reduced, such as the removal of a power supply. Please refer to the “Understanding Priority Disconnect” on page 4-10 for additional details. OmniSwitch 6560 Hardware Users Guide December 2019 page 4-9...
  • Page 84: Understanding Priority Disconnect

    For example: -> lanpower slot 2/1 priority-disconnect disable Enabling Priority Disconnect To enable priority disconnect, use the lanpower slot priority-disconnect command. For example: -> lanpower slot 2/1 priority-disconnect enable page 4-10 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 85: Priority Disconnect Is Enabled; Same Priority Level On All Pd

    When a PD is being connected to a port with a lower priority level than all other in the slot, the incoming PD will be denied power, regardless of its physical port number. Devices connected to other higher-prior- ity will continue operating without interruption. OmniSwitch 6560 Hardware Users Guide December 2019 page 4-11...
  • Page 86: Priority Disconnect Is Disabled

    When priority disconnect is disabled, power will be denied to any incoming PD, regardless of its port priority status (i.e., low, high, and critical) or physical port number (i.e., 1–24). page 4-12 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 87: Monitoring Power Over Ethernet Via Cli

    Undefined 30000 Undefined 30000 Undefined Slot 3 Max Watts 150 1 Power Supplies Available Note. For detailed information on show lanpower command output, refer to the OmniSwitch CLI Refer- ence Guide. OmniSwitch 6560 Hardware Users Guide December 2019 page 4-13...
  • Page 88 Monitoring Power over Ethernet via CLI Managing Power over Ethernet (PoE) page 4-14 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 89: Regulatory Compliance And Safety Information

    Switzerland and therefore marked with the following symbol: Treatment applied at end of life of the product in these countries shall comply with the applicable national laws implementing directive 2002/96/EC on waste electrical and electronic equipment (WEEE). OmniSwitch 6560 Hardware Users Guide December 2019 page A-1...
  • Page 90: China Rohs: Hazardous Substance Table

    China RoHS: Hazardous Substance Table Regulatory Compliance and Safety Information China RoHS: Hazardous Substance Table page A-2 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 91: Taiwan Rohs: Hazardous Substance Table

    Regulatory Compliance and Safety Information Taiwan RoHS: Hazardous Substance Table Taiwan RoHS: Hazardous Substance Table OmniSwitch 6560 Hardware Users Guide December 2019 page A-3...
  • Page 92: California Proposition 65 Warning

    State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov. Products are packaged using one or more of the following packaging materials: Corrugated Cardboard Corrugated Fiberboard Low-Density Polyethylene page A-4 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 93: Standards Compliance

    BSMI, Taiwan (Contact for availability) • KCC, Korea (Contact for availability) • In compliance with UL/EN/IEC 62368-1: This equipment is not suitable for use in locations where children are likely to be present. OmniSwitch 6560 Hardware Users Guide December 2019 page A-5...
  • Page 94 • IEC 60068-2-13 • IEC 60068-2-40 • IEC 60068-2-41 • IEC 6068-2-6 • IEC 60068-2-64 • IEC 60068-2-27 • GR-63-CORE • MIL-STD-810F Method 516.5 IV • MIL-STD-810F Method 516.5 C • page A-6 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 95: Fcc Class A, Part 15

    CISPR22 Class A warning This is a Class A product. In a domestic environment, this product may cause radio interference. Under such circumstances, the user may be requested to take appropriate countermeasures. OmniSwitch 6560 Hardware Users Guide December 2019 page A-7...
  • Page 96: Korea Emissions Statement

    Class 1M Laser Warning CLASS 1M LASER RADIATION WHEN OPEN. DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS. Network Cable Installation Warning Never install exposed network cables outdoors. Install network cables per manufacturer requirements. page A-8 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 97: Translated Safety Warnings

    Deutsch: Dieses Gerät soll nur von Personal installiert oder gewartet werden, welches in elektrischen und mechanischen Grundlagen ausgebildet ist. Español: Estos equipos deben ser instalados y atendidos exclusivamente por personal adecuadamente formado y capacitado en técnicas eléctricas y mecánicas. OmniSwitch 6560 Hardware Users Guide December 2019 page A-9...
  • Page 98: Invisible Laser Radiation Warning

    Netzverbindungen getrennt sind bevor das Gerät gewartet oder bewegt wird. Español: Antes de empezar a trabajar con un sistema, asegurese que el interruptor está cerrado y el cable eléctrico desconectado. page A-10 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 99: Proper Earthing Requirement Warning

    Erde angeschlossen werden. Español: Para EMC/EMI, cada fuente de alimentación de CC/CC requiere que el cable de tierra esté conectado desde cada fuente de alimentación de CC/CC a la conexión a tierra común. OmniSwitch 6560 Hardware Users Guide December 2019 page A-11...
  • Page 100: Read Important Safety Information Warning

    Español: Debido a las descargas electrostáticas (ESD) puede dañar los componentes del interruptor, debe seguir los procedimientos adecuados para eliminar la EDS de su persona y sus alrededores antes de manipular los componentes del interruptor. page A-12 OmniSwitch 6560 Hardware Users Guide December 2019...
  • Page 101 Deseche las baterías usadas según las instrucciones del fabricante. Las instrucciones del fabricante son como sigue: Devuelva el módulo con la batería del litio a Alcatel-Lucent. La batería del litio será substituida en la fábrica de Alcatel-Lucent.
  • Page 102 Para este propósito, Alcatel-Lucent proporciona una pulsera antiestática y un terminal que pone a tierra situados cerca de la parte superior derecha del chasis. Para que la pulsera antiestática sea eficaz en la eliminación de ESD, las fuentes de alimentación se deben instalar en el chasis y enchufar en las salidas de CA con descarga a...

Table of Contents